Conceptpower DPA 500 (modular UPS)

Conceptpower DPA 500 (modular UPS)

Three phase From 1000kW to 3MV

Three-phase modular ups from 1000kW to 3MV. Large datacenters – Mid-sized datacenters – Server rooms and IT applications – Critical process protection. Conceptpower DPA 500 each 100 kW power module is its own working UPS. System power can always be scaled to fit the load power without need to oversize, or being able to predict the growing power demand to far future. More modules can be added at any stage to increase system capacity.

Description

Conceptpower DPA 500 modular UPS price in Bangladesh

Conceived for medium-sized and large data centers, ABB’s Conceptpower DPA 500 modular uninterruptible power supply (UPS) fulfils power requirements from 100 kW to 3 MW and provides maximum availability for those who aim for zero downtime as well as a low cost at Orient BD Ltd.

Total vertical and horizontal scalability

The Conceptpower DPA 500 delivers power protection from 100 to 500 kW (one to five modules) in a single cabinet (vertical scalability). Cabinets can operate in a parallel configuration to build a system of up to 3 MW (horizontal scalability).

True parallel architecture

The advanced UPS design of Conceptpower DPA 500 provides the highest degree of protection in critical applications where the load must be fed with quality power. This UPS system utilizes decentralized parallel architecture and ensures the highest level of reliability and availability with the best UPS service provider in Bangladesh.

Technical specifications:

General data  400V IEC  480V UL
System power range 100 kW – 3000 kW
UPS module rated power 100 kW
UPS cabinet rated power 500 kW  300 kW / 500 kW
UPS output rated PF 1.0
Parallel configuration 500 kW Cabinet:
Up to 5 modules
in one cabinet
Up to 6 cabinets
in parallel/3MW
300 kW Cabinet:
Up to 3 modules
in one cabinet
Up to 4 cabinets
in parallel/1.2MW500 kW Cabinet:
Up to 5 modules
in one cabinet
Up to 6 cabinets
in paralle/3MW
Wiring 3ph + N + PE 3ph + PE
UPS type Modular, Decentralized Parallel Architecture (DPA)
Topology Online double conversion
Serviceability Front access only
Input  400V IEC  480V UL
Nominal input voltage 220/380, 230/400,
240/415 VAC
3 x 480VAC
Voltage range <  100% (-10%,+15%)
<  80% (-20%,+15%)
<  60% (-30%,+15%)
Frequency range 35-70 Hz 60 Hz
Current THD at 100% load < 3.5 %
Power Factor at 100% load 0.99
Output  400V IEC  480V UL
Rated output voltage 220/380, 230/400, 240/415 VAC 3 x 480VAC
Voltage THD (with linear load) < 2 %
Frequency 50 or 60 Hz (selectable)  60 Hz
Efficiency  400V IEC  480V UL
Online double conversion Up to 96% >96%
Eco-mode ≥99%
Communications
User interface Graphical touch screen (one per frame as standard) Decentralized LCD + mimic diagram (one per module as standard)
Communication ports (optional) USB, RS-232, potential-free contacts, SNMP
RS-485, Modbus TCP/IP, SNMP, BACnet
Customer interface (400 V IEC only) Remote shutdown, gen-set interface, external bypass contact
Compliancy  400V IEC  480V UL
Safety IEC/EN 62040-1 UL 1778 5th edition, CSA C22.2 No. 107.3-14 3rd Ed.
EMC IEC/EN 62040-2 IEC/EN 62040-2 C3
Performance IEC/EN 62040-3 IEC/EN 62040-3
Manufacturing ISO 9001:2008, ISO 14001:2004 ISO 9001:2008

Technical specifications are subject to change without notice.