UB (6-10kVA)

UB (6-10kVA)

True double-conversion

UB 6-10K UPS can supply reliable power to the data centre, crucial load, meet the high reliability of customer for UPS. UB is with high efficiency and can supply comprehensive power protection for the user.

You can checkout UB 6-10K UPS price in Bangladesh.

Description

General Features

● True double-conversion

● DSP technology guarantees high reliability

● N+X parallel redundancy

● Selectable quantity of battery for each group:16/18/20 pieces

● Adjustable charging current via LCD

● 3-stage charging design optimizes battery performance

● ECO mode operation for energy saving

● Self-diagnosis at startup

● Emergency power off function(EPO)

● Maintenance bypass is convenient for maintenance

● Generator compatible

● Communications:RS-232,USB,SNMP card(Optional), Relay card (Optional)

● Cold start

Technical Specification

MODEL UB60 UB60L UB100 UB100L
Capacity (VA/Watts) 6K / 5.4K 10K / 9K
INPUT
Nominal Voltage  220/230/240Vac(L+N+PE)
Operating Voltage Range 120Vac-276Vac
Operating Frequency Range 50Hz:45~55Hz,60Hz:54~66Hz
Power Factor ≥0.99
Bypass Voltage Range Max.voltage: 220V:+25%(Optional +10%,+15%,+20% )
         230V:+20%(Optional +10%,+15%)
240V:+15%(Optional +10% )
  Min. voltage: -45% (Optional -20%,-30%)
ECO Range Same as bypass
Harmonic Distortion (THDi) ≤5%(100% non-linear load)
OUTPUT
Output Voltage 220/230/240Vac
Power Factor 0.9
Voltage Regulation ±1%
Frequency Line Mode ±1%/±2%/±4%/±5%/±10% of the rated frequency(Optional)
Bat. Mode (50/60±0.1)Hz
Crest Factor 3:1
Harmonic Distortion (THDv) ≤2% with linear load
≤5% with non-linear load
Waveform Pure Sinewave
Transfer Time Utility to Battery : 0ms; Utility to Bypass: 0ms
EFFICIENCY
Efficiency Up to 94%
BATTERY
Battery Voltage Selectable Voltage: ±96/108/120Vdc
Typical Recharge Time 6-8 hours (To 90% capacity)
Charging Current Maximum current 10A
PROTECTION
Overload Line Mode Load≤125%: last 5min;≤150%: last 1min;>150% 200ms turn to bypass mode
Bypass Mode 40A(Input breaker) 60A(Input breaker)
Short Circuit Hold Whole System
Overheat Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Battery Low Alarm and Switch off
INDICATORS
Audible & Visual Alarms Line Failure, Battery Low, Overload, System Fault
Status LED & LCD Display Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault
Parameters On The LCD Panel Input/Output Voltage, Input/Output Frequency, Load Level, Battery Level,
Inner Temperature & Remaining    Battery Backup Time
MANAGEMENT
Communication Interface RS-232,USB,Parallel card(Optional), SNMP card(Optional), Relay card (Optional)
ENVIRONMENT
Operating Temperature 0℃~40℃
Storage Temperature -25℃~55℃
Humidity Range 0~95% (Non-condensing)
Altitude < 1500m
Noise Level <55dB
PHYSICAL
Dimension W×D×H (mm) 250×502×616 220×481×438 250×502×616 220×481×438
Net Weight (kg) 62 18 64 20
STANDARDS
Noise Suppression Complies with EN62040-2
Safety IEC/EN62040-1,IEC/EN60950-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
BATTERY PACK
Model EXB±120V
Battery type& Max.quantity 7Ah×40/9Ah×40
Dimensions W×D×H (mm) 250×502×616
Net Weight (kg) 125.8/138