UC (10-20kVA)

UC (10-20kVA)

Three-phase or 1-phase input

UC100-200 series UPS is a three phase in and one phase out high frequency tower-mounted UPS with medium and small power capacity, output power factor reach up to 0.9, realize strong load capacity, and adopting leading DSP online double conversion technology, fully meet the uninterruptable power supply requirement for the user load. Flexible battery quantity configuration, flexible redundancy design, compatiblity to generator access, greatly increase the availability of UPS. This series UPS is widely used in small and medium IDC machine room, control center, industry process control fields and so on.

Description

General Features

● True double-conversion

● DSP technology guarantees high reliability

● N+X parallel redundancy

● Compatible with 3 phases and single phase input

● Selectable quantity of battery for each group:16/18/20 pieces

● Adjustable charging current via LCD

● 3-stage charging design optimizes battery performance

● ECO mode operation for energy saving

● Self-diagnosis at startup

● Emergency power off function(EPO)

● Maintenance bypass is convenient for maintenance

● Generator compatible

● Communications:RS-232,USB,Parallel card(Optional),SNMP card(Optional), Relay card (Optional)

● Cold start

Technical Specification

MODEL UC100 UC100L UC150L UC200L
Capacity (VA/Watts) 10K / 9K 15K / 13.5K 20K / 18K
INPUT
Nominal Voltage 380/400/415Vac(3Ph+N+PE) or 220/230/240Vac(L+N+PE)
Operating
Voltage Range
208~478Vac or 120VAC-276Vac
Operating
Frequency Range
50Hz:45~55Hz,60Hz:54~66Hz
Power Factor ≥0.99
Bypass
Voltage Range
Max.voltage: 220V:+25%(Optional +10%,+15%,+20% )
         230V:+20%(Optional +10%,+15%)
240V:+15%(Optional +10% )
   Min. voltage: -45% (Optional -20%,-30%)
ECO Range Same as bypass
Harmonic
Distortion (THDi)
≤5%(100% non-linear load)
OUTPUT
Rated Voltage 220/230/240Vac
Power Factor 0.9
Voltage Regulation ±1%
Frequency Line Mode ±1%/±2%/±4%/±5%/±10% of the rated
frequency(Optional)
Bat. Mode (50/60±0.1)Hz
Crest Factor 3:1
Harmonic
Distortion (THD)
≤2% with linear load
≤5% with non-linear load
Waveform Pure Sinewave
Transfer Time Utility to Battery : 0ms; Utility to Bypass: 0ms
EFFICIENCY
Efficiency Up to 94% Up to 94.5%
BATTERY
Battery Voltage Selectable Voltage: ±96/108/120Vdc
Typical
Recharge Time
6-8 hours (To 90% capacity)
Charging Current Maximum current 10A
PROTECTION
Overload Line Mode Load≤125%: last 5min;≤150%: last 1min;>150% 200ms
turn to bypass mode
Bypass Mode 63A(Input breaker) 100A(Input breaker) 125A(Input breaker)
Short Circuit Hold Whole System
Overheat Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Battery Low Alarm and Switch off
INDICATORS
Audible &
Visual Alarms
Line Failure, Battery Low, Overload, System Fault
Status LED &
LCD Display
Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low,
Battery Bad, Overload & UPS Fault
Parameters On
The LCD Panel
Input/Output Voltage, Input/Output Frequency, Load Level, Battery Level,
Inner Temperature & Remaining Battery Backup Time
MANAGEMENT
Communication
Interface
RS-232,USB,Parallel card(Optional), SNMP card(Optional), Relay card (Optional)
ENVIRONMENT
Operating Temperature 0℃~40℃
Storage Temperature -25℃~55℃
Humidity Range 0~95% (Non-condensing)
Altitude < 1500m
Noise Level <55dB <58dB
PHYSICAL
Dimension
W×D×H (mm)
250×597×655 250×502×616
Net Weight (kg) 76 35 45 46
STANDARDS
Noise Suppression Complies with EN62040-2
Safety IEC/EN62040-1,IEC/EN60950-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8