Apollo 20 KVA Online UPS (3×3 Phase)
- Brand: Apollo
- Country of Origin: Taiwan
- Country of Manufacturing: Taiwan
- Model: 3P20K
- Type: Online
- Capacity: 20kva 3:3 Phase
- No internal battery – Long Backup
Description
Apollo 20kva online UPS has true on-line dual conversion design and also it is generator compatible. This UPS has All types of protections such as: over/low-voltage, overcurrent and overload. Intelligent Battery Management, extended battery life and intelligent Self diagnose function, all kinds of fault protection. Modularized design of subsystems. Apollo 20kva Bypass back feed protection, battery leakage protection. Parallel redundancy design, increase the system reliability. Customizable wide input voltage range. It has large size input LCD display on front panel.
Apollo 20 KVA Online UPS (3×3 Phase)
Model | 3P20K | |
Capacity (VA/Watts) | 20K/16K | |
INPUT | ||
Nominal voltage | 380/400/415Vac, (3Ph+N+PE) | |
Operating voltage range | 208~478Vac | |
Operating frequency range | 40 ~ 70Hz | |
Power factor | ≥0.99 | |
Harmonic distortion (THD) | 2%(100% nonlinear load) | |
Bypass voltage range | Max. Voltage: 220V +25% (optional +10%, +15%, +20%) 230V 20% (optional +10%, +15%)
240V 15% (optional +10%), Min voltage: -45% (optional -20%, -30%), Frequency protection rage: ±10% |
|
Generator input | Support | |
OUTPUT | ||
Output voltage | 380/400/415Vac, (3Ph+N+PE) | |
Voltage regulation | ±1% | |
Power factor | 0.8/0.9 (Customized) | |
Output frequency | 1.Line Mode: ±1%/±2%/±4%/±5%/±10% of the rated frequency (optional)
2.Battery Mode: (50/60±0.2%)Hz |
|
Crest factor | 3:1 | |
Harmonic distortion (THDv) | ≤2% with linear load
≤5% with non linear load |
|
Efficiency | 94.5% | |
BATTERY | ||
Battery voltage | Standard unit: ±216Vdc; Long run unit Optional voltage: ±192V\±204V\±216V\±228V\±240Vdc | |
Battery type | 12V/38Ah (standard unit) | |
Charge Current (A)
(charge current can be set according to battery capacity installed) |
12A (Max.) | |
SYSTEM FEATURES | ||
Transfer time | Utility to Batter : 0ms; Utility to bypass: 0ms | |
Overload | Line Mode | Load ≤110%: last 60min, ≤125%: last 1min, ≥150% turn to bypass mode immediately |
Bat. Mode | Load ≤110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, ≥150% shut down UPS immediately | |
Short circuit | Hold Whole System | |
Overheat | Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately | |
Low battery voltage | Alarm and Switch off | |
Self-diagnostics | Upon Power On and Software Control | |
EPO (optional) | Shut down UPS immediately | |
Battery | Advanced Battery Management | |
Nose Suppression | Complies with EN62040-2 | |
Audible & Visual | Line Failure, Battery Low, Overload System Fault | |
Status LED & LCD display | Line Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault | |
Reading on the LCD display | Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature | |
Communication interface | RS232, RS485, Parallel, Intelligent slot, Relay card (optional), SNMP card (optional) | |
ENCIRONMENTAL | ||
Operating temperature | 0~40°C | |
Storage temperature | -25 ~ 55°C | |
Humidity range | 0 ~ 95% (non ─ condensing) | |
Altitude | <1500m | |
Noise level | <55dB | |
PHYSICAL | ||
Dimension W x D x H (mm) | 780 x 600 x 1200 | |
Net weight (KG) | S:602
H:133 |
|
STANDARDS | ||
Safety | IEC/EN62040-1; IEC/EN60950-1 | |
EMC | IEC/EN602040-2; IEC61000-4-2: IEC61000-4-3; IEC61000-4-4;
IEC61000-4-5; IEC61000-4-6; IEC 61000-4-8 |